Register | Login | Set as Home Page | Bookmark | General Enquiries | Help | Tuesday, 07th of October 2008
IPE Logo
ipesearch.com
Search 
Magazine 
Click to visit http://www.ni.com/greenengineering



Get your free copy today!


In association with
Igus

Register for our ENewsletter
Click to visit sponsors web site

Click to visit sponsors web site

Click to visit sponsors web site

Click to visit http://air.irco.com/uk/

Click to visit sponsors web site

Click to visit sponsors web site

Click to visit sponsors web site

Click to visit sponsors web site

Click to visit sponsors web site

Click to visit sponsors web site

Click here to visit the Energy Event website



Click here for the latest compressed air news !

Removes oil mist
May 1st 2007

Carter Environmental Engineers (CEE) has installed an abatement plant to remove oil mist generated during the cold reduction of sheet steel products at the Llanwern steelworks of Corus.

Four carter-Midac Pacific oil mist collectors remove oil mist prior to discharge to atmosphere, with a guaranteed emission level of 5mg/Nm3 and anticipated emission level of 1mg/Nm3.

The mist is a water-based coolant with a 2 to 4.5% oil content, plus any particulate collected by the mist.

Pacific oil mist units are of the coalescing type and use four stages of filtration: the first is a stainless steel coarse mesh filter pad; the second a polypropylene coalescing filter; the third and fourth stages use an ultra high efficiency cellular inertial filter made of plastic that removes virtually all the mist droplets.

More articles from Carter Environmental Engrs Ltd: