In-line flame arresters
July 1st 2008

Designed and made exclusively for Edwards' CDX range of chemical dry vacuum pumps, the latest in-line flame arresters from Elmac Technologies make use of a highly specialised heat transfer medium which can be shaped to fit the small space available in the suction and discharge sections of a pump.

Under normal operating conditions, this medium allows gas to pass through the pump with minimal resistance to flow. However, in the event that the gas is ignited within the pump, the medium extinguishes the flames, thereby protecting upstream and downstream equipment from the consequences of a deflagration or detonation.

The CDX pump range uses the latest screw pumping technology in a rugged, non-contacting design. This allows control of the pump body or stator and internal gas temperatures, enabling a range of solvents, flammables and corrosives in to be pumped.