How to prevent operator bypass
Safety guard interlocks help protect operators when working with rotating equipment and other high-risk machinery. However, interlocks are vulnerable to manipulation, putting operators in danger from unsafe machinery, explains David Dearden
THERE ARE many reasons operators may want to bypass guard interlocks, and often it comes down to efficiency. For example, staff may want to keep a robot cell door open so they can perform maintenance without having to shut down a machine.
Typically, safety interlocks consist of a safety switch and an actuator. If the actuator is accessible, there may be a greater motivation to remove and use it to bypass the interlock. One option is hiding the actuator in the door frame, so operators don’t know it’s there. However, often when they see non-contact switches, operators may remove the actuator and tape it to the switch so the door can open and close without breaking the safety circuit.
Even if the actuator is hidden from view, this may not stop maintenance staff and other operators from using a spare actuator as an override key. If they do, the guard system may not know that the safety signal was being manipulated, which could leave the robot cell and operators vulnerable.
Incorporating a startup test into the control system can help discourage operators from tampering with switches or actuators. For example, a startup test could require each guard to open and close at the start of every shift, so, if an operator did remove an actuator and tape it to the switch, it would be easier to spot. First, they would need to un-tape the actuator and put it in its original place ready for the test, before removing it again and re-taping it after the test to continue bypassing.