Edward Lowton
Editor |
![]() ![]() |
Home> | Premises management/maintenance | >Boilers & burners | >J Series vertical fuel-fired steam boiler and JFS (Flash steam) vertical fuel fired steam boiler |
Home> | Plant, Process & Control | >Boilers and burners | >J Series vertical fuel-fired steam boiler and JFS (Flash steam) vertical fuel fired steam boiler |
Home> | Energy Management | >Boilers and burners | >J Series vertical fuel-fired steam boiler and JFS (Flash steam) vertical fuel fired steam boiler |
J Series vertical fuel-fired steam boiler and JFS (Flash steam) vertical fuel fired steam boiler
04 May 2016
The J Series is designed to meet the steam raising requirements for process steam across industrial, pharmaceutical, medical, food and drinks industry applications.

Its tubeless design, invented by Fulton, eliminates coils and tubes traditionally used in a steam raising plant and enable the J Series to raise its full steam output in just 20 minutes.
The boilers feature increased thermal efficiency, with reduced flue gas and casing temperatures.
Modulating burners are available, including retro fit modulating burners for 30J - 60J boilers
The J Series is robustly constructed with a simple, compact design, and a minimal footprint. It is easy to service and maintain, with good access for cleaning and inspection.
Constructed to BS 2790:1992 Class 1 as standard, these boilers provide operating pressures up to 10.34 bar and offer thermal efficiencies greater than 80% gross c.v. 88% net c.v.
· 8 Models: 60kW - 600kW
· Output: 96 kg/h – 960 kg/h (F & A 100˚C)
· Operating Pressure 10.34 barg
· vertical gas- and oil-fired
· Low NOx gas burner
· Fully Modulated Gas Burner Available (LPG and Propane burners available)
· Five Year Guarantee on Pressure Vessel
The boilers can be supplied as a factory-built, skid-mounted package where the boiler, feedwater tank, blowdown vessel and water treatment system are incorporated with all interconnecting mechanical and electrical services.
JFS (Flash steam) vertical fuel fired steam boiler
The JFS incorporates a large heat transfer surface and is able to meet peak demand for steam over a relatively short period - ideal for peaky steam loads such as sterilisers and autoclave applications.
· 3 Models: 100kW - 200kW
· 160 kg/h - 320 kg/h Steady State
· 300 kg/h - 680 kg/h Peak Demand
· Operating Pressure 10.34 barg
· Low NOx gas burner
· Five Year Guarantee on Pressure Vessel
The boilers can be supplied as a factory-built, skid-mounted package where the boiler, feedwater tank, blowdown vessel and water treatment system are incorporated with all interconnecting mechanical and electrical services.